Generating sets driven by diesel  Lombardini engine

Three Phase (III) Air Cooled 1500 rpm, 400/230 V 50 Hz

      Power kVA/kW    Weight    Dimensions  
Model Engine  Prime  Standby  approx. Kg    (length/width/height)  
 AL 6     4LD820    6,5/5,2    7,3/5,8    260    1200X620X900  
 AL 10     9LD625    10/8,0    11/8,8    340    1290X620X1000  
 AL 15   11LD626    15/12    16,5/13,2   380    1290X620X1000  

 
Three Phase (III) Water Cooled 1500 rpm, 400/230 V 50 Hz

      Power kVA/kW  
Model Engine  Prime  Standby
 AL 8    LDW1003    8/6,4    8,5/6,8  
 AL 11   LDW1404    11/8,8    12,5/10  
 AL 16    LDW1603    15/12    16,5/13,2  
 AL 20    LDW2204    19/15,2    20/16  

Single Phase (II) Water Cooled 1500 rpm, 230 V 50 Hz

      Power kVA/kW  
Model Engine  Prime  Standby
 AL 8    LDW1003    7,75/6,2    8,5/6,8  
 AL 11   LDW1404    10,75/8,6    11,9/9,5  
 AL16     LDW1603    14,25/11,4   15,75/12,6 
 AL20    LDW2204    18/14,5    20/16  

Engine heater and battery charger is standard with AMF and auto + LTS. Circuit breaker is also included in the price.


 

Scope of supply:   Manual / Remote  
Engine and alternator are assembled on a rigid monobloack with axles connection by a flexible disc. The monoblock is mounted on a steel chassis standing on anti-vibration montings. The chassis has a fuel tank. The start is electrical and includes a batter  The control panel is controlled by a manual / remote start module equipped with analogue gauges to know voltage, amperage, frequency, fuel level and running hours. 4-pole circuit breaker is standard up to 85 kva while 3-pole breaker is used for the rest 
Details of panels
Automatic control panel            
The control panel is controlled by a standby module with automatic start in event of a utility. The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency. It also protects engine and alternator through alarms and genset shutdown if any anomaly might happen. Running hours, coolant heater and battery charger are included.

Please note that remote AMF panel that include LTS and the mounted automatic panel with remote LTS do the same function which is to start the set automatically in case of failure of the grid. The only difference is that the panel and the LTS are remote in case of the AMF panel.
Details of panels for  upto 200 KVA
 
 All sets conform to European Stage 2                                                        
Prime Power: Available electrical power (at variable load), with an average of 80% of the maximum power mentioned), subject to an overload of 10% during 1hour in 12 hours
Standby Power: Available electrical power (at variable load) during a maximum of 500 hours in a year. NO overload is permitted.                   

To view dimensions of water cooled please click here